STABILITY-INDICATING RP-HPLC-UV METHOD FOR ESTIMATION OF IVABRADINE AND METOPROLOL SUCCINATE IN TABLET DOSAGE FORM
Keywords:
Ivabradine, Metoprolol Succinate, RP-HPLC, Method development, Validation, Stability-indicating, ICH guidelines, pharmaceutical analysisAbstract
A simple, accurate, precise, and stability-indicating RP-HPLC-UV method was developed and validated for the simultaneous estimation of Ivabradine and Metoprolol Succinate in tablet dosage form. The chromatographic separation was achieved using an Agilent C18 (150 × 4.6 mm, 5 µm) column with a mobile phase consisting of Methanol:0.1% OPA (50:50, v/v) at a flow rate of 0.8 mL/min. The column temperature was maintained at 30°C with UV detection at 260.0 nm. The retention times for Ivabradine and Metoprolol were 2.210 min and 2.650 min, respectively. The method exhibited excellent precision with %RSD values of 0.4% and 0.6% for Ivabradine and Metoprolol, respectively. Recovery studies yielded 99.89% and 100.09% for Ivabradine and Metoprolol, respectively. Limits of detection (LOD) and quantification (LOQ) were 0.02 and 0.06 µg/mL for Ivabradine, and 0.24 and 0.74 µg/mL for Metoprolol, respectively. Linear regression equations were y = 33598x + 1032 for Ivabradine and y = 43436x + 2678 for Metoprolol with excellent correlation coefficients of 0.999. The developed method was validated according to ICH Q2(R2) guidelines and demonstrated to be simple, economical, stability-indicating, and suitable for routine quality control testing in pharmaceutical industries.
References
[1] Singh R. HPLC method development and validation – an overview. Journal of Pharmaceutical Education & Research. 2013;4(1):10-20.
[2] ICH Q2(R1). Validation of analytical procedures: text and methodology. International Conference on Harmonisation; 2005.
[3] Bhardwaj SK, Dwivedi K, Agarwal DD. A review: HPLC method development and validation. International Journal of Analytical and Bioanalytical Chemistry. 2015;5(4):76-81.
[4] Seerapu S, Srinivasan BP. RP-HPLC method for estimation of Ivabradine Hydrochloride. Pharmaceutical Methods. 2011;2(3):203-207.
[5] Muzaffar-ur-Rehman M, Nagamallika G. Development and validation of RP-HPLC method for Ivabradine Hydrochloride. Journal of Pharmacy Research. 2014;8(5):645-652.
[6] Mahaparale S, Gonjari ID, Jayaveera KN. RP-HPLC method for simultaneous estimation of Metoprolol and Telmisartan. Research Journal of Pharmaceutical, Biological and Chemical Sciences. 2011;2(3):989-998.
[7] Kumar P, Selva, Pandiyan, Rajagopa. Development of RP-HPLC method for Ivabradine Hydrochloride in bulk and tablet dosage form. Asian Journal of Pharmaceutical Analysis. 2013;3(2):78-85.
[8] Naveen Kumar CH, Saraswathi M, Kuchana V. RP-HPLC method development and validation for Metoprolol Succinate. International Journal of Pharmaceutical Sciences and Research. 2012;3(10):3987-3993.
[9] Panda S, Patra S. UV and RP-HPLC methods for estimation of Ivabradine. Asian Journal of Research in Chemistry. 2013;6(4):345-352.
[10] Bhosale SD, Vanjari SS, Jagtap NS. UV-VIS spectrophotometric method for determination of Ivabradine. Journal of Pharmaceutical and Biomedical Analysis. 2012;2(3):156-164.
Downloads
Published
Issue
Section
License
Copyright (c) 2025 INTERNATIONAL JOURNAL OF PHARMACEUTICAL RESEARCH AND BIOMEDICAL ANALYSIS

This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License.
![]()

This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License. Based on a work at www.ijprba.com
"The content of IJPRBA journal and the published Manuscripts are copy right protected. Commercial usage of the same is prohibited.
Click here for obtaining Permission for commercial use"